MONITOR | Solenoid Drivers

To discuss the full range of Solenoid Drivers supplied by Automated Control, please contact us.

Contact Us
MTL5521

MTL5521 Loop Powered Solenoid Driver IIC

  • Loop-powered module which enables a device located in the hazardous area to be controlled from the
    safe area
  • Can drive a certified intrinsically safe low-power load, as well as non-energy-storing simple apparatus such as an LED
  • MTL4521-L-5521 Data Sheet

 

MTL5500-MS

MTL5523 Solenoid Driver with LFD

  • An on/off device in a hazardous area can be controlled by a volt-free contact or logic signal in the safe area
  • Suitable for driving loads such as solenoids
  • Includes line fault detection (LFD)
  • MTL4523-R-5523 Data Sheet

 

MTL5500-MS

MTL5524 Switch Operated Solenoid Driver

  • Enables an on/off device in a hazardous area to be controlled by a volt-free contact or logic signal in the safe area
  • Can be phase reversed
  • MTLx524 Data Sheet

 

MTL5500-MS

MTL5526 2ch Switch Operated Relay

  • Enables two separate IS circuits in a hazardous area to be contact controlled by one or two, on/off, control signals in a safe area
  • Output–relay contacts are certified as non–energy–storing apparatus, and can be connected to any IS circuit without further certification
  • MTLx526 Data Sheet
MTL5522Oblique

MTL5522 Loop Powered Solenoid Driver IIB

  • Loop-powered module which enables a device located in the hazardous area to be controlled from the
    safe area
  • Can drive a certified intrinsically safe low-power load
  • Input/output isolation allows the control switch to be connected into either side of the 24V dc supply circuit.
  • MTL5522 Data Sheet
MTL5500-MS

MTL5523V – VL Solenoid/Alarm Driver with Voltage Control

  • An on/off device in a hazardous area can be controlled by a voltage signal in the safe area
  • It is suitable for driving loads such as solenoids
  • Includes line fault detection (LFD)
  • MTLx523V-VL Data Sheet

MTL5525 Loop powered Solenoid Driver Low Power

  • Enables an on/off device in a hazardous area to be controlled by a volt-free contact or logic signal in the safe area
  • Can drive loads such as solenoids, alarms, LEDs and other low power devices that are certified as intrinsically safe
  • MTLx525 Data Sheet