skip to Main Content
+61 2 4964 4022 sales@automatedcontrol.com.au
Sense | Monitor | Control
Sense | Monitor | Control
Sense | Monitor | Control
Sense | Monitor | Control
Sense | Monitor | Control
Sense | Monitor | Control
previous arrow
next arrow
 
Shadow

Application

Monitoring detonation pressure within a test facility.

Key Requirements

  • Fast response time to enable the capture of detonation pressure profile
  • Hazardous area approval for local market
  • Capable of withstanding periodic overpressure demands
  • High process temperature compatibility
  • Stability of output

Solution

STS ATM.ECO/Ex pressure transmitter with the following key features;

  • Response time of less than 1ms over 10-90% of full scale range
  • Australian sourced IECEx intrinsically safe approval for hazardous areas
  • Overpressure rating of 3X full scale range with a burst pressure of greater than 850bar
  • Capable of operating with process temperature of up to 150 deg C
  • Long term stability of less than 0.1% of full scale per annum
Back To Top