Application
Monitoring detonation pressure within a test facility.
Key Requirements
- Fast response time to enable the capture of detonation pressure profile
- Hazardous area approval for local market
- Capable of withstanding periodic overpressure demands
- High process temperature compatibility
- Stability of output
Solution
STS ATM.ECO/Ex pressure transmitter with the following key features;
- Response time of less than 1ms over 10-90% of full scale range
- Australian sourced IECEx intrinsically safe approval for hazardous areas
- Overpressure rating of 3X full scale range with a burst pressure of greater than 850bar
- Capable of operating with process temperature of up to 150 deg C
- Long term stability of less than 0.1% of full scale per annum