STS | Pressure Monitoring

Country of Origin

Switzerland

Established

1987

Core Competency

Customised solutions for pressure measurement

Products

Pressure and temperature transmitters
Submersible level sensors
Data logging devices

To view the full range of STS products supplied by Automated Control, please visit the STS products.

STS website

STS-logo-200

Pressure and Temperature Transmitters

STS-productpicture_atm-1st

ATM.1ST

  • Pressure measuring range: 100 mbar … 1000 bar
  • Accuracy: ≤ ± 0.10 / 0.05 % FS
  • Operating temperature: -40 … 125°C
  • STS ATM.1ST Data Sheet
STS-productpicture_atm-1st-ex

ATM.1ST/IS

  • Pressure measuring range: 100 mbar … 1000 bar
  • Accuracy: ≤ ± 0.10 / 0.05 % FS
  • Operating temperature: -40 … 125°C
  • STS ATM.1ST/IS Data Sheet
STS-productpicture_atm-eco

ATM.ECO

  • Pressure measuring range: 100 mbar … 1000 bar
  • Accuracy: ≤ ± 0.25 % FS
  • Operating temperature: -40 … 125°C
  • STS ATM.ECO Data Sheet
STS-productpicture_atm-eco-ex

ATM.ECO/IS

  • Pressure measuring range: 100 mbar … 1000 bar
  • Accuracy: ≤ ± 0.25 % FS
  • Operating temperature: -40 … 125°C
  • STS ATM.ECO/IS Data Sheet
STS-productpicture_atm-ex

ATM/IS

  • Pressure measuring range: 100 mbar … 1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -25 … 85°C
  • STS ATM/IS Data Sheet
STS-productpicture_atm-f

ATM/F

  • Pressure measuring range: 100 mbar … 25 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -25 … 85°C
  • STS ATM/F Data Sheet
STS-productpicture_atm-f-ex

ATM/F/IS

  • Pressure measuring range: 100 mbar … 25 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -25 … 85°C
  • STS ATM/F/IS Data Sheet
STS-productpicture_ptm

PTM

  • Pressure measuring range: 100 mbar…1000 bar
  • Adjustable: 1:4 of the nominal range within -5% to +105%
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • STS PTM Data Sheet
STS-productpicture_ptm-n-rs-485

PTM/RS485

  • Pressure measuring range: 100 mbar … 1000 bar
  • Adjustable 1:4 of the nominal range within -5% to +105%
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • STS PTM/RS485 Data Sheet
STS-productpicture_atm-1st-ex

ATM.1ST/Ex

  • Pressure measuring range: 100 mbar … 1000 bar
  • Accuracy: ≤ ± 0.10 / 0.05 % FS
  • Operating temperature: -40 … 125°C
  • STS ATM.1ST/Ex Data Sheet
STS-productpicture_atm-1st-t

ATM.1ST/T

  • Pressure measuring range: 100 mbar … 25 bar
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Temperature measuring range: -50 … 150°C
  • STS ATM.1ST/T Data Sheet
STS-productpicture_atm-eco-ex

ATM.ECO/Ex

  • Pressure measuring range: 100 mbar … 1000 bar
  • Accuracy: ≤ ± 0.25 % FS
  • Operating temperature: -40 … 125°C
  • STS ATM.ECO/Ex Data Sheet
STS-productpicture_atm

ATM

  • Pressure measuring range: 100 mbar … 1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -25 … 85°C
  • STS ATM Data Sheet
STS-productpicture_atm-ex

ATM/Ex

  • Pressure measuring range: 100 mbar … 1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -25 … 85°C
  • STS ATM/Ex Data Sheet
STS-productpicture_atm-f-ex

ATM/F/Ex

  • Pressure measuring range: 100 mbar … 25 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -25 … 85°C
  • STS ATM/F/Ex Data Sheet
dtm.ocs_.s-Digital-pressure-sensor

DTM.OCS.S

  • Pressure measuring range: 200 mbar…100 bar
  • Accuracy: ≤ ± 0.15 / 0.05 / 0.03 % FS
  • Operating temperature: -40…85 °C
  • STS DTM.OCS.S Data Sheet
STS-productpicture_ptm-ex

PTM/Ex

  • Pressure measuring range: 100 mbar … 1000 bar
  • Adjustable 1:4 of the nominal range within -5% to +105%
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • STS PTM/Ex Data Sheet
STS-productpicture_ts-100

TS 100

  • Temperature measuring range: -50 … 150°C
  • Operating temperature: -25 … 85°C
  • Process temperature: -50 … 150°C
  • STS TS 100 Data Sheet

Submersible Level and Temperature Transmitters

STS-ATM.1ST_N_T

ATM.1ST/N/T

  • Pressure measuring range: 1 … 250 mH2O
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Temperature measuring range: -5 … 80°C
  • STS ATM.1ST/N/T Data Sheet
STS-productpicture_atm-1st-n-ex

ATM.1ST/N/EX

STS-productpicture_atm-eco-n-ex

ATM.ECO/N/Ex

STS-productpicture_atm-n-ex

ATM/N/IS

  • Pressure measuring range: 1 … 250 mH2O
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -5 … 80°C
  • STS ATM/N/IS Data Sheet
STS-productpicture_atm-n-t

ATM/N/T

  • Multi-parameter diving probe: pressure and temperature
  • Pressure measuring range: 1 … 250 mH2O
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • STS ATM/N/T Data Sheet
STS-productpicture_ptm-n-ex

PTM/N/Ex

  • Scalable pressure ranges and output signals
  • Flexibly applicable pressure sensor
  • Pressure measuring range: 1…250 mH2O
  • STS PTM/N/Ex Data Sheet
STS-productpicture_mtm-n-10

MTM/N 10

  • Submersible level transmitter with a very small diameter
  • Pressure measuring range: 10…100 mH2O
  • Accuracy: ≤ ± 0.50 / 0.25
  • STS MTM/N 10 Data Sheet
STS-productpicture_atm-1st-n

ATM.1ST/N

STS-productpicture_atm-eco-n

ATM.ECO/N

STS-productpicture_atm-n

ATM/N

  • Pressure measuring range: 1 … 250 mH2O
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Re-calibration possible
  • STS ATM/N Data Sheet
STS-productpicture_atm-n-ex

ATM/N/EX

  • Pressure measuring range: 1 … 250 mH2O
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -5 … 80°C
  • STS ATM/N/Ex Data Sheet
STS-productpicture_ptm-n

PTM/N

  • Scalable pressure ranges and output signals
  • Flexibly applicable pressure sensor
  • Pressure measuring range: 1…250 mH2O
  • STS PTM/N Data Sheet
STS-productpicture_ptm-n-sdi-12

PTM/N/SDI-12

  • Scalable pressure ranges and output signals
  • Pressure measuring range: 5…250 mH2O
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • STS PTM/N/SDI-12 Data Sheet
STS-productpicture_tm-n-ex

TM/N/Ex

  • Unreinforced output signal
  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.50 / 0.25 % FS
  • STS TM/N/Ex Data Sheet

Watermanager Solution & Data Loggers

GetAttachment-data-logger

DL.OCS/N/RS485 Datalogger

STS-productpicture_dl-wms-gprs-r

DL.WMS/GPRS/R Watermanager Solution