STS | Pressure Monitoring
Country of Origin
Switzerland
Established
1987
Core Competency
Customised solutions for pressure measurement
Products
Pressure and temperature transmitters
Submersible level sensors
Data logging devices
To view the full range of STS products supplied by Automated Control, please visit the STS products.

Pressure and Temperature Transmitters

ATM.1ST
- Pressure measuring range: 100 mbar … 1000 bar
- Accuracy: ≤ ± 0.10 / 0.05 % FS
- Operating temperature: -40 … 125°C
- STS ATM.1ST Data Sheet

ATM.1ST/IS
- Pressure measuring range: 100 mbar … 1000 bar
- Accuracy: ≤ ± 0.10 / 0.05 % FS
- Operating temperature: -40 … 125°C
- STS ATM.1ST/IS Data Sheet

ATM.ECO
- Pressure measuring range: 100 mbar … 1000 bar
- Accuracy: ≤ ± 0.25 % FS
- Operating temperature: -40 … 125°C
- STS ATM.ECO Data Sheet

ATM.ECO/IS
- Pressure measuring range: 100 mbar … 1000 bar
- Accuracy: ≤ ± 0.25 % FS
- Operating temperature: -40 … 125°C
- STS ATM.ECO/IS Data Sheet

ATM/IS
- Pressure measuring range: 100 mbar … 1000 bar
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- Operating temperature: -25 … 85°C
- STS ATM/IS Data Sheet

ATM/F
- Pressure measuring range: 100 mbar … 25 bar
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- Operating temperature: -25 … 85°C
- STS ATM/F Data Sheet

ATM/F/IS
- Pressure measuring range: 100 mbar … 25 bar
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- Operating temperature: -25 … 85°C
- STS ATM/F/IS Data Sheet

PTM
- Pressure measuring range: 100 mbar…1000 bar
- Adjustable: 1:4 of the nominal range within -5% to +105%
- Accuracy: ≤ ± 0.25 / 0.10 % FS
- STS PTM Data Sheet

PTM/RS485
- Pressure measuring range: 100 mbar … 1000 bar
- Adjustable 1:4 of the nominal range within -5% to +105%
- Accuracy: ≤ ± 0.25 / 0.10 % FS
- STS PTM/RS485 Data Sheet

ATM.1ST/Ex
- Pressure measuring range: 100 mbar … 1000 bar
- Accuracy: ≤ ± 0.10 / 0.05 % FS
- Operating temperature: -40 … 125°C
- STS ATM.1ST/Ex Data Sheet

ATM.1ST/T
- Pressure measuring range: 100 mbar … 25 bar
- Accuracy: ≤ ± 0.25 / 0.10 % FS
- Temperature measuring range: -50 … 150°C
- STS ATM.1ST/T Data Sheet

ATM.ECO/Ex
- Pressure measuring range: 100 mbar … 1000 bar
- Accuracy: ≤ ± 0.25 % FS
- Operating temperature: -40 … 125°C
- STS ATM.ECO/Ex Data Sheet

ATM
- Pressure measuring range: 100 mbar … 1000 bar
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- Operating temperature: -25 … 85°C
- STS ATM Data Sheet

ATM/Ex
- Pressure measuring range: 100 mbar … 1000 bar
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- Operating temperature: -25 … 85°C
- STS ATM/Ex Data Sheet

ATM/F/Ex
- Pressure measuring range: 100 mbar … 25 bar
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- Operating temperature: -25 … 85°C
- STS ATM/F/Ex Data Sheet

DTM.OCS.S
- Pressure measuring range: 200 mbar…100 bar
- Accuracy: ≤ ± 0.15 / 0.05 / 0.03 % FS
- Operating temperature: -40…85 °C
- STS DTM.OCS.S Data Sheet

PTM/Ex
- Pressure measuring range: 100 mbar … 1000 bar
- Adjustable 1:4 of the nominal range within -5% to +105%
- Accuracy: ≤ ± 0.25 / 0.10 % FS
- STS PTM/Ex Data Sheet

TS 100
- Temperature measuring range: -50 … 150°C
- Operating temperature: -25 … 85°C
- Process temperature: -50 … 150°C
- STS TS 100 Data Sheet
Submersible Level and Temperature Transmitters

ATM.1ST/N/T
- Pressure measuring range: 1 … 250 mH2O
- Accuracy: ≤ ± 0.25 / 0.10 % FS
- Temperature measuring range: -5 … 80°C
- STS ATM.1ST/N/T Data Sheet

ATM.1ST/N/EX
- Various certificates available
- Pressure measuring range: 1…250 mH2O
- Accuracy: ≤ ± 0.10 % FS
- STS ATM.1ST/N/Ex Data Sheet

ATM.ECO/N/Ex
- Various certificates available
- Pressure measuring range: 1 … 250 mH2O
- Accuracy: ≤ ± 0.25 % FS
- STS ATM.ECO/N/Ex Data Sheet

ATM/N/IS
- Pressure measuring range: 1 … 250 mH2O
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- Operating temperature: -5 … 80°C
- STS ATM/N/IS Data Sheet

ATM/N/T
- Multi-parameter diving probe: pressure and temperature
- Pressure measuring range: 1 … 250 mH2O
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- STS ATM/N/T Data Sheet

PTM/N/Ex
- Scalable pressure ranges and output signals
- Flexibly applicable pressure sensor
- Pressure measuring range: 1…250 mH2O
- STS PTM/N/Ex Data Sheet

MTM/N 10
- Submersible level transmitter with a very small diameter
- Pressure measuring range: 10…100 mH2O
- Accuracy: ≤ ± 0.50 / 0.25
- STS MTM/N 10 Data Sheet

ATM.1ST/N
- Electronic compensation
- Pressure measuring range: 1 … 250 mH2O
- Accuracy: ≤ ± 0.10 % FS
- STS ATM.1ST/N Data Sheet

ATM.ECO/N
- Electronic compensation
- Pressure measuring range: 1 … 250 mH2O
- Accuracy: ≤ ± 0.25 % FS
- STS ATM.ECO/N Data Sheet

ATM/N
- Pressure measuring range: 1 … 250 mH2O
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- Re-calibration possible
- STS ATM/N Data Sheet

ATM/N/EX
- Pressure measuring range: 1 … 250 mH2O
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- Operating temperature: -5 … 80°C
- STS ATM/N/Ex Data Sheet

PTM/N
- Scalable pressure ranges and output signals
- Flexibly applicable pressure sensor
- Pressure measuring range: 1…250 mH2O
- STS PTM/N Data Sheet

PTM/N/SDI-12
- Scalable pressure ranges and output signals
- Pressure measuring range: 5…250 mH2O
- Accuracy: ≤ ± 0.25 / 0.10 % FS
- STS PTM/N/SDI-12 Data Sheet

TM/N/Ex
- Unreinforced output signal
- Pressure measuring range: 1…250 mH2O
- Accuracy: ≤ ± 0.50 / 0.25 % FS
- STS TM/N/Ex Data Sheet

DL.OCS/N/RS485 Datalogger
- Pressure measuring range: 0…250 mH2O
- Interface: RS485
- Stainless steel, titanium
- STS DL.OCS/N/RS485 Data Sheet

DL.WMS/GPRS/R Watermanager Solution
- Process temperature: -5 … 80°C
- Radio interface: 433 MHz
- Data transfer: GSM/GPRS
- STS DL.WMS/GPRS/R Data Sheet