![MTL5500-MS MTL5500-MS](https://automatedcontrol.com.au/wp-content/uploads/MTL5500-MS-250x250.jpg)
MTL5314 Trip Amplifier
- One Channel with two configurable alarms
- Signal Range 0-24ma
- MTL5314 Data Sheet
![KFD2-GS-1.2W KFD2-GS-1.2W](https://automatedcontrol.com.au/wp-content/uploads/KFD2-GS-1.2W.png)
Current/Voltage Trip Value KFD2-GS-1.2W
- 1-channel signal conditioner
- 24 V DC supply (Power Rail)
- Current and voltage input
- 2 relay outputs
- Programmable high/low alarm
- Configurable via DIP switches and potentiometer
- Terminal blocks with test sockets
- KFD2-GS-1.2W Data Sheet
![KFD2-GUT-1D KFD2-GUT-1D](https://automatedcontrol.com.au/wp-content/uploads/KFD2-GUT-1D.png)
Temperature Converter with Trip Values KFD2-GUT-1.D
- 1-channel signal conditioner
- 24 V DC supply (Power Rail)
- Thermocouple, RTD, potentiometer or voltage input
- Redundant TC input
- Current output 0/4 mA … 20 mA
- KFD2-GUT-1D Data Sheet
![KFD2-WAC2-1D KFD2-WAC2-1D](https://automatedcontrol.com.au/wp-content/uploads/KFD2-WAC2-1D.png)
Strain Gauge Converter KFD2-WAC2-1.D
- 1-channel signal conditioner
- 24 V DC supply (Power Rail)
- Strain gauge input (full or half bridge)
- Output 0 mA … ± 20 mA or 0 V … ± 10 V
- Relay contact output
- Programmable high/low alarm
- KFD2-WAC2-1.D Data Sheet
![KFU8-USC-1d KFU8-USC-1d](https://automatedcontrol.com.au/wp-content/uploads/KFU8-USC-1d.png)
Signal Converter with Trip Value KFU8-USC-1.D
- 1-channel signal conditioner
- Universal usage at different power supplies
- Scaleable current or voltage input
- Current or voltage output
- Relay contact output
- Configurable by keypad
- Line fault detection (LFD)
- KFU8-USC-1.D Data Sheet
![KFD2-CRG2-1D KFD2-CRG2-1D](https://automatedcontrol.com.au/wp-content/uploads/KFD2-CRG2-1D.png)
KFD2-CRG2-1.D Transmitter Power Supply
- 1-channel signal conditioner
- Input 2-wire and 3-wire transmitters and 2-wire current sources
- Output 0/4 mA … 20 mA
- 2 relay contact outputs
- Programmable high/low alarm
- KFD2-CRG2-1.D Data Sheet
![KFD2-GU-1 KFD2-GU-1](https://automatedcontrol.com.au/wp-content/uploads/KFD2-GU-1.png)
Temperature Trip Amplifier KFD2-GU-1
- 1-channel signal conditioner
- 24 V DC supply (Power Rail)
- Thermocouple, RTD, voltage or current input
- 2 relay contact outputs
- Programmable high/low alarm
- Configurable by PACTware
- Sensor breakage detection
- KFD2-GU-1 Data Sheet
![KFD2-USC-1D KFD2-USC-1D](https://automatedcontrol.com.au/wp-content/uploads/KFD2-USC-1D.png)
Signal Converter with Trip Value KFD2-USC-1.D
- 1-channel signal conditioner
- 24 V DC supply (Power Rail)
- Scaleable current or voltage input
- Current or voltage output
- Relay contact output
- Configurable by keypad
- Line fault detection (LFD)
- KFD2-USC-1.D Data Sheet
![KFU8-CRG2-1D KFU8-CRG2-1D](https://automatedcontrol.com.au/wp-content/uploads/KFU8-CRG2-1D.png)
Transmitter Power Supply KFU8-CRG2-1.D
- 1-channel signal conditioner
- Universal usage at different power supplies
- Input 2-wire and 3-wire transmitters and 2-wire current sources
- Output 0/4 mA … 20 mA
- 2 relay contact outputs
- Programmable high/low alarm
- KFU8-CRG2-1.D Data Sheet